Basic Knowledge of Site Engineer
Following few general points to remember for site engineers to make the construction work easier while maintaining the quality of construction.
- Lapping is not allowed for the bars having diameters more than 36mm.
- Chair spacing maximum spacing is 1.00m or 1 no per 1m2.
- For dowels rod minimum of 12mm diameter should be used.
- Chairs minimum of 12mm diameter bars to be used.
- Longitudinal reinforcement not less than 0.8% and more than 6% of gross C/S.
- Minimum bars of square column is 4 numbers and 6 numbers for circular column.
- Main bars in the slabs shall not be less than 8mm (HYSD) or 10mm (Plain Bars) and distributors not less than 8mm and not more than 1/8 of slab thickness.
- Minimum thickness of slab is 125mm.
- Dimension tolerance for cubes +- 2mm.
- Free fall of concrete is allowed maximum to 1.50m.
- Lap slice not to be used for bar larger than 36mm.
- Water absorption of bricks should not be more than 15%.
- PH value of water should not be less than 6.
- Compressive strength of bricks is 3.5N/mm2.
- In steel reinforcement binding wire required is 8kg per MT.
- In soil filling as per IS code, 3 samples should be taken for core cutting test for every 100m2.